Date-Issued: 04/23/2001 CONCRETE FORM OIL |
MANUFACTURERAlbright & Wilson Americas Inc.Surfactants Division P.O. Box 4439 Glen Allen, VA 23058-4439 Contact: Product Stewardship Department Product Stewardship: (804) 968-6496 Transportation: (804) 968-6418 |
24 HR. EMERGENCY TELEPHONE NUMBERSCHEMTREC (U.S.): (800) 424-9300Canutec (613) 996-6666 Emergency Phone: (803) 554-1229 |
| Chemical Name | Wt.% | CAS# | EINECS# | ||
|---|---|---|---|---|---|
| Severely Hydrotreated Heavy Naphthenic Distillate | >95 | 64742-52-5 | 265-155-0 | ||
| Poly(oxy-1,2-ethanediyl),-(nonly1phenyl)-w-hydroxy | <1 | 9016-45-9 | xxx-xxx-x | ||
| OXYGENATED HYDROCARBONS | <5 | AM#420-04-0 | |||
SMALL SPILL:
Extinguish posssible sources of ignition and ventilate spill area. Dike area to contain spill and clean up by absorbing on an inert absorbent or other convenient means. Do not flush into sewers or natural waterways. Non-essential personnel should not enter area due to slipping hazards.LARGE SPILL:
Contain material as described above and call the local fire or police department for immediate emergency assistance.HANDLING:
Use appropriate personal protective equipment as specified in Section 8. Handle in a well ventilated area.STORAGE:
Store unopened containers under cool, dry and ventilated conditions. Keep away from heat, sparks and flame.| EXPOSURE LIMITS | |||||||
|---|---|---|---|---|---|---|---|
| OSHA PEL | ACGIH TLV | Supplier OEL | |||||
| ppm | mg/m3 | ppm | mg/m3 | ppm | mg/m3 | ||
| Severely Hydrotreated Heavy Naphthenic Distillate | TWA | 5 | 5[1] | ||||
| OXYGENATED HYDROCARBONS | TWA | 5 | 5 | ||||
1. Oil Mist
REVISION SUMMARY
New MSDS